Tunghai University Institutional Repository:Item 310901/22507
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 21921/27947 (78%)
造訪人次 : 4250743      線上人數 : 422
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://140.128.103.80:8080/handle/310901/22507


    題名: A small/wide-angle X-ray scattering instrument for structural characterization of air-liquid interfaces, thin films and bulk specimens
    作者: Jeng, U.-S. , Su, C.H., Su, C.-J., Liao, K.-F., Chuang, W.-T., Lai, Y.-H., Chang, J.-W., Chen, Y.-J., Huang, Y.-S., Lee, M.-T., Yu, K.-L., Lin, J.-M., Liu, D.-G., Chang, C.-F., Liu, C.-Y., Chang, C.-H., Liang, K.S.
    關鍵詞: Air-water interfaces;Anomalous scattering;Grazing-incidence small-angle X-ray scattering (GISAXS);Small-angle X-ray scattering (SAXS);Wide-angle X-ray scattering (WAXS)
    日期: 2010
    上傳時間: 2013-05-21T09:08:34Z (UTC)
    出版者: Department of Chemistry, Tunghai University
    摘要: At the National Synchrotron Radiation Research Center, a small/wide-angle X-ray scattering (SAXS/WAXS) instrument has been installed at the BL23A beamline with a superconducting wiggler insertion device. This beamline is equipped with double Si(111) crystal and double Mo/B4C multilayer monochromators, and an Si-based plane mirror that can selectively deflect the beam downwards for grazing-incidence SAXS (GISAXS) studies of air-liquid or liquid-liquid interfaces. The SAXS/WAXS instrument, situated in an experimental hutch, comprises collimation, sample and post-sample stages. Pinholes and slits have been incorporated into the beam collimation system spanning a distance of ?5 m. The sample stage can accommodate various sample geometries for air-liquid interfaces, thin films, and solution and solid samples. The post-sample section consists of a 1 m WAXS section with two linear gas detectors, a vacuum bellows (1-4 m), a two-beamstop system and the SAXS detector system, all situated on a motorized optical bench for motion in six degrees of freedom. In particular, the vacuum bellows of a large inner diameter (260 mm) provides continuous changes of the sample-to-detector distance under vacuum. Synchronized SAXS and WAXS measurements are realized via a data-acquisition protocol that can integrate the two linear gas detectors for WAXS and the area detector for SAXS (gas type or Mar165 CCD); the protocol also incorporates sample changing and temperature control for programmable data collection. The performance of the instrument is illustrated via several different measurements, including (1) simultaneous SAXS/WAXS and differential scanning calorimetry for polymer crystallization, (2) structural evolution with a large ordering spacing of ?250 nm in a supramolecular complex, (3) SAXS for polymer blends under in situ drawing, (4) SAXS and anomalous SAXS for unilamellar lipid vesicles and metalloprotein solutions, (5) anomalous GISAXS for oriented membranes of Br-labeled lipids embedded with peptides, and (6) GISAXS for silicate films formed in situ at the air-water interface. ? 2010 International Union of Crystallography Printed in Singapore-all rights reserved.
    關聯: Journal of Applied Crystallography 43 (1) , pp. 110-121
    顯示於類別:[化學系所] 期刊論文

    文件中的檔案:

    檔案 大小格式瀏覽次數
    index.html0KbHTML118檢視/開啟


    在THUIR中所有的資料項目都受到原著作權保護.


    本網站之東海大學機構典藏數位內容,無償提供學術研究與公眾教育等公益性使用,惟仍請適度,合理使用本網站之內容,以尊重著作權人之權益。商業上之利用,則請先取得著作權人之授權。

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋