    Title: 印刷電路板製程減廢之探討
    Other Titles: A study on the waste minimization for printed circuit board manufacture.
    Authors: 王欽江
    Wang, C.J
    Contributors: 謝樹木
    Hsieh, Shu-Mu
    東海大學化學工程與材料工程學系
    Keywords: 印刷電路板;減廢;蒸發;逆滲透
    Printed circuit board;Waste minimization;Evaporation;Reverse osmosis
    Date: 1993
    Issue Date: 2011-06-16T01:10:25Z (UTC)
    Abstract: 本文主要針對印刷電路板製程水洗水,應用蒸發和逆滲透分離單元回收再 利用水洗液中的藥液和水洗水。對於製程槽電路板帶出量120l/d,帶出液 濃度32500ppm,水洗以後電路板帶出液濃度等於5ppm的操作情況下,探討 帶出量比值D和槽數n對於製程水洗水回收的影響,經由經濟分 析,找出 蒸發和逆滲透回收系統最佳水洗槽數及回收年限。蒸發回收系統模擬結果 顯示,當D=1時,使用蒸發器回收水洗液,最佳選擇為槽數n=6,蒸發器所 需加熱面積為0.26m,投資回收年限 3.05年。若 D=0.1,最佳蒸發回收系 統,槽數n=5,蒸發器所需加熱面積0.06m,投資回收年限為1.75年。逆滲 透回收系統模擬結果顯示,當D=1時,使用逆滲透器回收水洗液,在有效 操作壓力為200psig時,最佳選擇為槽數n=4,逆滲透器所需逆滲透膜面積 為21.7m,投資回收年限1.49年。若D=0.1,最佳逆滲透回收系統,槽數 n=3,逆滲透膜面積為10.2m,投資回收年限為1年。對於蒸發和逆滲透回 收系統,經由模擬結果,在不同 D值情況下,均可求出最佳回收系統設計 和回收年限,電腦程式如附錄。
    Appears in Collections:[化學工程與材料工程學系所] 碩博士論文

    Files in This Item:

    File SizeFormat
    index.html0KbHTML258View/Open


    All items in THUIR are protected by copyright, with all rights reserved.


    本網站之東海大學機構典藏數位內容,無償提供學術研究與公眾教育等公益性使用,惟仍請適度,合理使用本網站之內容,以尊重著作權人之權益。商業上之利用,則請先取得著作權人之授權。

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback